Probe-sensing rules¶
The probe-sensing rules score a child whose exploration method is one of the probing methods:
[Probing (onshore, lake, river, etc.)], [Probing (offshore, ocean)] and
[Probing (clustered)]. They give a T-score for the temperature gradient and a TC-score for
the thermal conductivity. Both start at 1.0 and each criterion adds a penalty, as
the overview describes, including what an empty and an unspecified input do.
Source for the whole page: Fuchs et al. (2023), with its corrigendum (Fuchs et al., 2026, Tectonophysics 934, 231226, https://doi.org/10.1016/j.tecto.2026.231226), Section 3.2.1 and Table 2. Later sources cite the corrigendum’s table as “corrected Table 2”.
T-score¶
The T-score has four criteria: the probe penetration, the number of temperature recordings, the water depth and the probe tilt. Its lowest value is 0.2 and its highest 1.2.
Fields read¶
Field code |
Published column name |
Name |
|---|---|---|
|
Type of exploration method |
|
|
Elevation (Geographical) |
|
|
Penetration depth |
|
|
Number of temperature recordings |
|
|
Probe tilt |
|
|
Flag temperature corrections (instrumental correction) |
|
|
Flag transient surface temperature (heat-flow correction) |
flowchart TD
gradient["Probe gradient"] --> penetration["Penetration"]
gradient --> recordings["Number of recordings"]
gradient --> corrected_water{"Bottom-water correction present and corrected?"}
corrected_water -->|"Yes"| water_waived["Water depth: no penalty"]
corrected_water -->|"No"| water["Water depth"]
gradient --> corrected_tilt{"Temperature correction tilt corrected?"}
corrected_tilt -->|"Yes"| tilt_waived["Tilt: no penalty"]
corrected_tilt -->|"No"| tilt["Tilt"]
penetration --> sum["T-score = the start value plus the penalties"]
recordings --> sum
water --> sum
water_waived --> sum
tilt --> sum
tilt_waived --> sum
Penetration¶
Reads C6 probe_penetration, in metres.
Probe penetration (m) |
Penalty |
|---|---|
More than 10 |
+0.1 |
More than 3, up to 10 |
0 |
More than 1, up to 3 |
−0.1 |
1 or less |
−0.2 |
Empty |
−0.2, with the mark |
The field takes a number only, so it has no unspecified value. Source: corrected Table 2, “Probe penetration”. The table’s ranges give each edge to one row.
Number of temperature recordings¶
Reads C37 T_number.
Number of temperature recordings |
Penalty |
|---|---|
More than 5 |
+0.1 |
More than 2, up to 5 |
0 |
More than 1, up to 2 |
−0.1 |
1 or less |
−0.2 |
Empty |
−0.2, with the mark |
Source: corrected Table 2, “Number of temperature points”.
Water depth¶
Reads P6 elevation, in metres. The water depth is the elevation with its sign reversed.
Water depth (m) |
Penalty |
|---|---|
More than 2500 |
0 |
More than 1500, up to 2500 |
−0.1 |
1500 or less |
−0.2 |
Empty |
−0.2, with the mark |
An elevation of zero or above has no water depth, so the criterion is treated as empty: see DEP-7.
Waived. When C17 corr_SUR_flag is [Present and corrected], the criterion takes no
penalty and no mark, even when the elevation is empty.
Source: corrected Table 2, “Water depth”, where the waiver is the bottom-water temperature flag
{corr_BWT_flag}. The template has no field of that name, and the scheme reads C17: see
DEP-8.
Tilt¶
Reads C23 probe_tilt, in degrees.
Probe tilt (degree) |
Penalty |
|---|---|
More than 30 |
−0.2 |
More than 10, up to 30 |
−0.1 |
0 or more, up to 10 |
0 |
Empty |
−0.2, with the mark |
Any other value |
−0.2 |
The range of C23 does not allow a negative tilt.
Waived. When C12 corr_T_flag is [Tilt corrected], the criterion takes no penalty and
no mark, even when the tilt is empty. The corrected table conditions the waiver on the in-situ
correction {corr_IS_flag}, and the scheme reads the temperature correction C12, whose
vocabulary holds [Tilt corrected]: see DEP-8 and GHFDB portal decision D11, “The probe tilt correction is read from the temperature correction”.
Source: corrected Table 2, “Tilt”.
TC-score¶
The TC-score has four criteria: the location, the saturation, the number of conductivity measurements and the pT conditions. Its lowest value is 0.2 and its highest 1.2. It reads nothing from the child, so the child’s own score and its TC-score are the same.
Fields read¶
Field code |
Published column name |
Name |
|---|---|---|
|
Type of exploration method |
|
|
Thermal conductivity location |
|
|
Thermal conductivity source |
|
|
Thermal conductivity method |
|
|
Thermal conductivity saturation |
|
|
TC number |
|
|
Thermal conductivity pT conditions |
flowchart TD
conductivity["Probe conductivity"] --> location["Location"]
conductivity --> saturation["Saturation, method, source and location together"]
conductivity --> literature{"Location literature?"}
literature -->|"Yes"| skip["Number is not scored"]
literature -->|"No"| number["Number of measurements"]
conductivity --> pt["pT conditions and method"]
location --> sum["TC-score = the start value plus the penalties"]
saturation --> sum
skip --> sum
number --> sum
pt --> sum
Location¶
Reads C42 tc_location.
Thermal conductivity location |
Penalty |
|---|---|
|
0 |
|
−0.1 |
|
−0.2 |
Empty |
−0.2, with the mark |
Any other value |
−0.2 |
Source: corrected Table 2, “Localization”.
Saturation¶
Reads C44 tc_saturation, with C43 tc_method, C41 tc_source and C42 tc_location.
The criterion is a list of rows. Every row whose conditions all hold counts, and the poorest
penalty wins.
Thermal conductivity saturation |
Thermal conductivity method |
Thermal conductivity source |
Thermal conductivity location |
Penalty |
|---|---|---|---|---|
|
|
|
any |
+0.1 |
|
|
|
any |
0 |
|
every value is |
any |
any |
0 |
|
every value is |
any |
any |
−0.1 |
|
every value is |
any |
any |
−0.2 |
any |
|
any |
|
−0.1 |
any |
|
any |
any |
−0.2 |
No row holds, and a field is empty |
— |
— |
— |
−0.2, with the mark |
No row holds, and no field is empty |
— |
— |
— |
−0.2 |
A laboratory method is one of the six [Lab …] methods. A row that asks for every value to be
one holds only when every value of C43 is a laboratory method, because the corrected table
adds the condition “{tc_method} is all with [Lab - ...]” to the onshore laboratory rows. A
child that lists a laboratory method beside another method is scored by the rows of the other
method, and the laboratory method fits no row.
Empty. A row holds whatever the fields it does not name contain, so an empty field matters only when no row holds without it. A laboratory conductivity with
C41empty is scored by the laboratory rows, which do not nameC41. When no row holds and a field some row names is empty, the criterion takes the empty outcome of the table. Every row namesC43, so an emptyC43always takes it.Unspecified. An unspecified saturation, source or location is a value. It takes part in the rows above and, where it satisfies none, takes the unmatched outcome, without the mark.
No row holds. A conductivity measured by
[Probe - continuous heating technique]fits no row. It is under discussion (https://github.com/ihfc-iugg/ghfdb/issues/42). The vocabulary ofC43has no[Other], so the corrected table’s row for it among the estimates has no term to score.The offshore on-board rows. The corrected table writes the method and source conditions once, against the first of its two offshore on-board rows. The scheme applies them to both.
Source: corrected Table 2, “Source type and saturation”.
Number of conductivity measurements¶
Reads C47 tc_number, and C42 for the exception.
Number of conductivity measurements |
Penalty |
|---|---|
More than 3 |
0 |
More than 1, up to 3 |
−0.1 |
1 or less |
−0.2 |
Empty |
−0.2, with the mark |
Left out when Thermal conductivity location is [Literature or unspecified]: the criterion then adds no penalty and no mark.
Source: corrected Table 2, “Number of conductivities”, with the condition that the location is not literature or unspecified.
Pressure and temperature conditions¶
Reads C45 tc_pT_conditions, with C43 tc_method. The criterion is a list of rows, scored
like the saturation.
Thermal conductivity pT conditions |
Thermal conductivity method |
Penalty |
|---|---|---|
|
|
+0.1 |
|
any |
0 |
|
any |
−0.1 |
|
any |
−0.2 |
No row holds, and a field is empty |
— |
−0.2, with the mark |
No row holds, and no field is empty |
— |
−0.2 |
Empty. A row holds whatever the fields it does not name contain. Only the first row names
C43, so an emptyC43matters only for actual in-situ conditions, and replicated, corrected and ambient conditions score by their own rows. When no row holds and a field some row names is empty, which is an emptyC45, or an emptyC43with actual in-situ conditions, the criterion takes the empty outcome of the table.Unspecified.
[Unspecified]is a value, and takes the penalty of its row without the mark.No row holds. Actual in-situ conditions with a method other than the pulse probe hold no row, and take the unmatched outcome.
Source: corrected Table 2, “pT conditions”.
Worked examples¶
The worked examples give a gradient for every criterion of the T-score,
including both waivers, and a conductivity for every criterion of the TC-score, including the
literature exception, the empty inputs, an unspecified saturation and several conductivity
methods. Whole children scored by these rules are the examples named P1 to P5.
Under discussion¶
https://github.com/ihfc-iugg/ghfdb/issues/42: how a conductivity measured with the continuous heating probe scores.