# Probe-sensing rules The probe-sensing rules score a child whose exploration method is one of the probing methods: `[Probing (onshore, lake, river, etc.)]`, `[Probing (offshore, ocean)]` and `[Probing (clustered)]`. They give a T-score for the temperature gradient and a TC-score for the thermal conductivity. Both start at 1.0 and each criterion adds a penalty, as [the overview](index.md) describes, including what an empty and an unspecified input do. Source for the whole page: Fuchs et al. (2023), with its corrigendum (Fuchs et al., 2026, Tectonophysics 934, 231226, ), Section 3.2.1 and Table 2. Later sources cite the corrigendum's table as "corrected Table 2". ## T-score The T-score has four criteria: the probe penetration, the number of temperature recordings, the water depth and the probe tilt. Its lowest value is {{ lowest('probe-t') }} and its highest {{ highest('probe-t') }}. ### Fields read {{ fields("P12", "P6", "C6", "C37", "C23", "C12", "C17") }} ```{mermaid} flowchart TD gradient["Probe gradient"] --> penetration["Penetration"] gradient --> recordings["Number of recordings"] gradient --> corrected_water{"Bottom-water correction present and corrected?"} corrected_water -->|"Yes"| water_waived["Water depth: no penalty"] corrected_water -->|"No"| water["Water depth"] gradient --> corrected_tilt{"Temperature correction tilt corrected?"} corrected_tilt -->|"Yes"| tilt_waived["Tilt: no penalty"] corrected_tilt -->|"No"| tilt["Tilt"] penetration --> sum["T-score = the start value plus the penalties"] recordings --> sum water --> sum water_waived --> sum tilt --> sum tilt_waived --> sum ``` ### Penetration Reads `C6` `probe_penetration`, in metres. {{ criterion('probe-t.penetration') }} The field takes a number only, so it has no unspecified value. Source: corrected Table 2, "Probe penetration". The table's ranges give each edge to one row. ### Number of temperature recordings Reads `C37` `T_number`. {{ criterion('probe-t.recordings') }} Source: corrected Table 2, "Number of temperature points". ### Water depth Reads `P6` `elevation`, in metres. The water depth is the elevation with its sign reversed. {{ criterion('probe-t.water-depth') }} An elevation of zero or above has no water depth, so the criterion is treated as empty: see {ref}`DEP-7 `. **Waived.** When `C17` `corr_SUR_flag` is `[Present and corrected]`, the criterion takes no penalty and no mark, even when the elevation is empty. Source: corrected Table 2, "Water depth", where the waiver is the bottom-water temperature flag `{corr_BWT_flag}`. The template has no field of that name, and the scheme reads `C17`: see {ref}`DEP-8 `. ### Tilt Reads `C23` `probe_tilt`, in degrees. {{ criterion('probe-t.tilt') }} The range of `C23` does not allow a negative tilt. **Waived.** When `C12` `corr_T_flag` is `[Tilt corrected]`, the criterion takes no penalty and no mark, even when the tilt is empty. The corrected table conditions the waiver on the in-situ correction `{corr_IS_flag}`, and the scheme reads the temperature correction `C12`, whose vocabulary holds `[Tilt corrected]`: see {ref}`DEP-8 ` and {{ decision(11) }}. Source: corrected Table 2, "Tilt". ## TC-score The TC-score has four criteria: the location, the saturation, the number of conductivity measurements and the pT conditions. Its lowest value is {{ lowest('probe-tc') }} and its highest {{ highest('probe-tc') }}. It reads nothing from the child, so the child's own score and its TC-score are the same. ### Fields read {{ fields("P12", "C42", "C41", "C43", "C44", "C47", "C45") }} ```{mermaid} flowchart TD conductivity["Probe conductivity"] --> location["Location"] conductivity --> saturation["Saturation, method, source and location together"] conductivity --> literature{"Location literature?"} literature -->|"Yes"| skip["Number is not scored"] literature -->|"No"| number["Number of measurements"] conductivity --> pt["pT conditions and method"] location --> sum["TC-score = the start value plus the penalties"] saturation --> sum skip --> sum number --> sum pt --> sum ``` ### Location Reads `C42` `tc_location`. {{ criterion('probe-tc.location') }} Source: corrected Table 2, "Localization". ### Saturation Reads `C44` `tc_saturation`, with `C43` `tc_method`, `C41` `tc_source` and `C42` `tc_location`. The criterion is a list of rows. Every row whose conditions all hold counts, and the poorest penalty wins. {{ criterion('probe-tc.saturation') }} A laboratory method is one of the six `[Lab …]` methods. A row that asks for every value to be one holds only when every value of `C43` is a laboratory method, because the corrected table adds the condition "`{tc_method}` is all with `[Lab - ...]`" to the onshore laboratory rows. A child that lists a laboratory method beside another method is scored by the rows of the other method, and the laboratory method fits no row. * **Empty.** A row holds whatever the fields it does not name contain, so an empty field matters only when no row holds without it. A laboratory conductivity with `C41` empty is scored by the laboratory rows, which do not name `C41`. When no row holds and a field some row names is empty, the criterion takes the empty outcome of the table. Every row names `C43`, so an empty `C43` always takes it. * **Unspecified.** An unspecified saturation, source or location is a value. It takes part in the rows above and, where it satisfies none, takes the unmatched outcome, without the mark. * **No row holds.** A conductivity measured by `[Probe - continuous heating technique]` fits no row. It is under discussion (). The vocabulary of `C43` has no `[Other]`, so the corrected table's row for it among the estimates has no term to score. * **The offshore on-board rows.** The corrected table writes the method and source conditions once, against the first of its two offshore on-board rows. The scheme applies them to both. Source: corrected Table 2, "Source type and saturation". ### Number of conductivity measurements Reads `C47` `tc_number`, and `C42` for the exception. {{ criterion('probe-tc.number') }} Source: corrected Table 2, "Number of conductivities", with the condition that the location is not literature or unspecified. ### Pressure and temperature conditions Reads `C45` `tc_pT_conditions`, with `C43` `tc_method`. The criterion is a list of rows, scored like the saturation. {{ criterion('probe-tc.pT') }} * **Empty.** A row holds whatever the fields it does not name contain. Only the first row names `C43`, so an empty `C43` matters only for actual in-situ conditions, and replicated, corrected and ambient conditions score by their own rows. When no row holds and a field some row names is empty, which is an empty `C45`, or an empty `C43` with actual in-situ conditions, the criterion takes the empty outcome of the table. * **Unspecified.** `[Unspecified]` is a value, and takes the penalty of its row without the mark. * **No row holds.** Actual in-situ conditions with a method other than the pulse probe hold no row, and take the unmatched outcome. Source: corrected Table 2, "pT conditions". ## Worked examples The [worked examples](worked-examples.md) give a gradient for every criterion of the T-score, including both waivers, and a conductivity for every criterion of the TC-score, including the literature exception, the empty inputs, an unspecified saturation and several conductivity methods. Whole children scored by these rules are the examples named `P1` to `P5`. ## Under discussion * : how a conductivity measured with the continuous heating probe scores.