U-score¶
The U-score grades the uncertainty of a child’s heat-flow value, from U1 (excellent) to U4
(poor). It is Ux when it cannot be determined. This page states the criterion, the fields it
reads and where each rule comes from.
Fields read¶
The coefficient of variation¶
The U-score is read from the coefficient of variation, the uncertainty as a percentage of the value:
coefficient of variation (%) = |C2| / |C1| × 100
The coefficient is rounded to six decimal places before it is classed. The sign of either number
is ignored, because a heat flow can be negative: a value of −40 mW/m² with an uncertainty of 12
mW/m² is a coefficient of 30 % and scores U4.
Coefficient of variation |
U-score |
Description |
|---|---|---|
Below 5 % |
|
Excellent |
5 % up to and including 15 % |
|
Good |
Above 15 % up to and including 25 % |
|
Ok |
Above 25 % |
|
Poor |
flowchart TD
start["Heat-flow value and its uncertainty"] --> filled{"Both filled and not zero?"}
filled -->|"No"| ux["Ux, not determined"]
filled -->|"Yes"| coefficient["Coefficient of variation: the uncertainty as a percentage of the value"]
coefficient --> classes["The class of the coefficient"]
classes --> u1["U1"]
classes --> u2["U2"]
classes --> u3["U3"]
classes --> u4["U4"]
Source: Fuchs et al. (2023), with its corrigendum (Fuchs et al., 2026, Tectonophysics 934,
231226, https://doi.org/10.1016/j.tecto.2026.231226), Section 3.1, Equation 2 and Table 1. The
corrected Table 1 classes a coefficient below 5 % as U1, up to 15 % as U2, up to 25 % as
U3 and above 25 % as U4, so a coefficient of exactly 15 % is U2 and one of exactly 25 % is
U3. The paper’s Equation 2 leaves out the factor of 100 that turns the ratio into a
percentage, and the scheme includes it: see DEP-17.
Empty, zero and unspecified¶
Input |
U-score |
|---|---|
|
|
|
|
|
|
|
|
Both fields take numbers only, so neither has an unspecified value. A U-score has no
missing-information mark, so an empty input gives Ux and nothing else.
An uncertainty of zero is not determined. Read literally, the paper’s equation gives a
coefficient of 0 % for it and so U1. The scheme treats it as not determined, as the toolbox
that scored the 2024 release does: see DEP-3. Source for Ux: corrected Table 1,
“not applicable”.
Worked examples¶
The worked examples give a child for every class, for the rounding, for a negative value and for each way a U-score is not determined.