U-score

The U-score grades the uncertainty of a child’s heat-flow value, from U1 (excellent) to U4 (poor). It is Ux when it cannot be determined. This page states the criterion, the fields it reads and where each rule comes from.

Fields read

Field code

Published column name

Name

C1

qc

Heat-flow value child

C2

qc_uncertainty

Heat-flow uncertainty child

The coefficient of variation

The U-score is read from the coefficient of variation, the uncertainty as a percentage of the value:

coefficient of variation (%) = |C2| / |C1| × 100

The coefficient is rounded to six decimal places before it is classed. The sign of either number is ignored, because a heat flow can be negative: a value of −40 mW/m² with an uncertainty of 12 mW/m² is a coefficient of 30 % and scores U4.

Coefficient of variation

U-score

Description

Below 5 %

U1

Excellent

5 % up to and including 15 %

U2

Good

Above 15 % up to and including 25 %

U3

Ok

Above 25 %

U4

Poor

        flowchart TD
    start["Heat-flow value and its uncertainty"] --> filled{"Both filled and not zero?"}
    filled -->|"No"| ux["Ux, not determined"]
    filled -->|"Yes"| coefficient["Coefficient of variation: the uncertainty as a percentage of the value"]
    coefficient --> classes["The class of the coefficient"]
    classes --> u1["U1"]
    classes --> u2["U2"]
    classes --> u3["U3"]
    classes --> u4["U4"]
    

Source: Fuchs et al. (2023), with its corrigendum (Fuchs et al., 2026, Tectonophysics 934, 231226, https://doi.org/10.1016/j.tecto.2026.231226), Section 3.1, Equation 2 and Table 1. The corrected Table 1 classes a coefficient below 5 % as U1, up to 15 % as U2, up to 25 % as U3 and above 25 % as U4, so a coefficient of exactly 15 % is U2 and one of exactly 25 % is U3. The paper’s Equation 2 leaves out the factor of 100 that turns the ratio into a percentage, and the scheme includes it: see DEP-17.

Empty, zero and unspecified

Input

U-score

C1 empty

Ux

C1 zero

Ux

C2 empty

Ux

C2 zero

Ux

Both fields take numbers only, so neither has an unspecified value. A U-score has no missing-information mark, so an empty input gives Ux and nothing else.

An uncertainty of zero is not determined. Read literally, the paper’s equation gives a coefficient of 0 % for it and so U1. The scheme treats it as not determined, as the toolbox that scored the 2024 release does: see DEP-3. Source for Ux: corrected Table 1, “not applicable”.

Worked examples

The worked examples give a child for every class, for the rounding, for a negative value and for each way a U-score is not determined.