Perturbation flags¶
The perturbation flags record which disturbing effects the authors of a heat-flow value
recognised, and whether they corrected for them. They are seven characters, one for each effect,
and they are the last part of the quality code: in U2.M3x.-e-PX-- they are -e-PX--. The flags
never change the U-score or the M-score.
Fields read¶
One field of the child holds the state of each effect. The order of the characters is the order of the table.
Position |
Flag |
Effect |
Field code |
Published column name |
|---|---|---|---|---|
1 |
|
Sedimentation |
|
|
2 |
|
Erosion |
|
|
3 |
|
Topography and bathymetry |
|
|
4 |
|
Paleoclimate |
|
|
5 |
|
Surface and bottom-water temperature variation |
|
|
6 |
|
Convection |
|
|
7 |
|
Heat refraction |
|
Source: Fuchs et al. (2023), Section 3.3 and Fig. 4. The paper’s Table 5 writes heat refraction
as h/H and swaps the fifth and sixth characters. Its text and its Fig. 4 write heat
refraction as R, with surface-temperature variation fifth and convection sixth, and the
scheme follows them: see DEP-2 and GHFDB portal decision D6, “Heat refraction is R, and the flags follow the paper’s figure order”.
The in-situ correction C11 and the temperature correction C12 write no flag. They enter the T-score and the TC-score instead.
How each flag is written¶
Each correction field takes one of five values.
Value of the field |
Character |
Meaning |
|---|---|---|
|
the upper-case letter |
The effect is present and was corrected |
|
the lower-case letter |
The effect is present and was not corrected |
|
|
The effect is present and assumed to be insignificant |
|
|
The effect was not recognised, or is assumed not to be present |
|
|
No information is held |
An empty field and an unspecified field are written the same way, as -. Source: Fuchs et al.
(2023), Section 3.3, where a minus sign stands for data with insufficient information, “empty or
unspecified”. The two differ only for the in-situ correction C11, where an
empty field sets the mark of a borehole TC-score and an unspecified one does not. Neither
writes a flag: GHFDB portal decision D14, “A correction recorded as - is unspecified, a missing one is empty”.
flowchart TD
field["One correction field of the child"] --> value{"Its value"}
value -->|"Present and corrected"| upper["Upper-case letter"]
value -->|"Present and not corrected"| lower["Lower-case letter"]
value -->|"Present and not significant"| big_x["X"]
value -->|"Not recognized"| small_x["x"]
value -->|"Unspecified or empty"| dash["-"]
upper --> flags["Seven characters in the order S E T P V C R"]
lower --> flags
big_x --> flags
small_x --> flags
dash --> flags
Worked examples¶
The worked examples give every flag in its position, as present and corrected and as present and not corrected, each of the other states, a child with no correction recorded, and children that record all seven.