Child fields

C1 · qc — Heat-flow value child

Fact

Value

Field code

C1

Published column name

qc

Name

Heat-flow value child

Meaning

Any kind of heat-flow value (qc).

Type

number, 1 decimal places

Unit

mW/m²

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

U-score

Range

-999999.9 to 999999.9

C2 · qc_uncertainty — Heat-flow uncertainty child

Fact

Value

Field code

C2

Published column name

qc_uncertainty

Name

Heat-flow uncertainty child

Meaning

Uncertainty (one standard deviation) of the heat-flow value [qc] estimated by an error propagation from uncertainty in thermal conductivity and temperature gradient or deviation from the linear regression of the Bullard plot (corrected preferred over measured gradient).

Type

number, 1 decimal places

Unit

mW/m²

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

U-score

Range

0 to 999999.9

C3 · q_method — Heat-flow method

Fact

Value

Field code

C3

Published column name

q_method

Name

Heat-flow method

Meaning

Principal method of heat-flow calculation from temperature and thermal conductivity data. Allowed entries: controlled vocabulary

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

6 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-method, in the IHFC Controlled Vocabularies as currently published.

C4 · q_top — Heat-flow interval top

Fact

Value

Field code

C4

Published column name

q_top

Name

Heat-flow interval top

Meaning

Describes the true vertical depth (TVD) of the top end of the heat-flow determination interval relative to the land surface/seafloor.

Type

number, 2 decimal places

Unit

m

Obligation

Mandatory (M)

Domain

Borehole and mine (B)

Quality relevance

M-score

Range

0 to 19999.9

Rules

CF-1

C5 · q_bottom — Heat-flow interval bottom

Fact

Value

Field code

C5

Published column name

q_bottom

Name

Heat-flow interval bottom

Meaning

Describes the true vertical depth (TVD) of the bottom end of the heat-flow determination interval relative to the land surface.

Type

number, 2 decimal places

Unit

m

Obligation

Mandatory (M)

Domain

Borehole and mine (B)

Quality relevance

M-score

Range

0 to 19999.9

Rules

CF-1

C6 · probe_penetration — Penetration depth

Fact

Value

Field code

C6

Published column name

probe_penetration

Name

Penetration depth

Meaning

Penetration depth of marine probe into the sediment.

Type

number, 2 decimal places

Unit

m

Obligation

Mandatory (M)

Domain

Probe sensing (S)

Quality relevance

M-score

Range

0 to 999.9

Rules

CF-2

C7 · publication_reference — Primary publication reference

Fact

Value

Field code

C7

Published column name

publication_reference

Name

Primary publication reference

Meaning

References of primary publication related to the respective heat-flow entry.

Type

string, up to 255 characters

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Guidance: Write the reference in the form [First author_Year_Title_Journal/ Publisher_doi]. Source: Decision D-22.

C8 · data_reference — Primary reference

Fact

Value

Field code

C8

Published column name

data_reference

Name

Primary reference

Meaning

References of primary data publication related to the respective heat-flow entry.

Type

string, up to 255 characters

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Guidance: Write the reference in the form [First author_Year_Title_Journal/ Publisher_doi]. Source: Decision D-22.

C9 · relevant_child — Relevant child

Fact

Value

Field code

C9

Published column name

relevant_child

Name

Relevant child

Meaning

Specifies whether the child entry is used for computation of representative location heat-flow values at the parent level or not.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

2 values, listed below

  • [Yes]

  • [No]

C10 · c_comment — General comments child level

Fact

Value

Field code

C10

Published column name

c_comment

Name

General comments child level

Meaning

Comments and further specifications to the individual reported heat-flow determination.

Type

string, up to 255 characters

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

C11 · corr_IS_flag — Flag in-situ thermal properties

Fact

Value

Field code

C11

Published column name

corr_IS_flag

Name

Flag in-situ thermal properties

Meaning

Specifies whether the in-situ pressure and temperature conditions were considered to the reported thermal conductivity value or not.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/in-situ, in the IHFC Controlled Vocabularies as currently published.

C12 · corr_T_flag — Flag temperature corrections (instrumental correction)

Fact

Value

Field code

C12

Published column name

corr_T_flag

Name

Flag temperature corrections (instrumental correction)

Meaning

Specifies if instrumental corrections to the measured temperature data were required and performed, e.g. for the tilt correction of probes.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/instrumental, in the IHFC Controlled Vocabularies as currently published.

C13 · corr_S_flag — Flag sedimentation effect (heat flow correction)

Fact

Value

Field code

C13

Published column name

corr_S_flag

Name

Flag sedimentation effect (heat flow correction)

Meaning

Specifies if sedimentation/subsidence effects with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/sedimentation, in the IHFC Controlled Vocabularies as currently published.

C14 · corr_E_flag — Flag erosion effect (heat-flow correction)

Fact

Value

Field code

C14

Published column name

corr_E_flag

Name

Flag erosion effect (heat-flow correction)

Meaning

Specifies if erosion effects with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/erosion, in the IHFC Controlled Vocabularies as currently published.

C15 · corr_TOPO_flag — Flag topographic effect (heat-flow correction)

Fact

Value

Field code

C15

Published column name

corr_TOPO_flag

Name

Flag topographic effect (heat-flow correction)

Meaning

Specifies if topographic effects with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/topography, in the IHFC Controlled Vocabularies as currently published.

C16 · corr_PAL_flag — Flag paleoclimatic effect (heat-flow correction)

Fact

Value

Field code

C16

Published column name

corr_PAL_flag

Name

Flag paleoclimatic effect (heat-flow correction)

Meaning

Specifies if climatic conditions (glaciation, post-industrial warming, etc.) with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/paleoclimate, in the IHFC Controlled Vocabularies as currently published.

C17 · corr_SUR_flag — Flag transient surface temperature (heat-flow correction)

Fact

Value

Field code

C17

Published column name

corr_SUR_flag

Name

Flag transient surface temperature (heat-flow correction)

Meaning

Specifies if surface temperature variation (S) or bottom water temperature variation (B) with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/transient-surface-temperature, in the IHFC Controlled Vocabularies as currently published.

C18 · corr_CONV_flag — Flag convection processes (heat-flow correction)

Fact

Value

Field code

C18

Published column name

corr_CONV_flag

Name

Flag convection processes (heat-flow correction)

Meaning

Specifies if convection effects with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/convection, in the IHFC Controlled Vocabularies as currently published.

C19 · corr_HR_flag — Flag heat refraction effect (heat-flow correction)

Fact

Value

Field code

C19

Published column name

corr_HR_flag

Name

Flag heat refraction effect (heat-flow correction)

Meaning

Specifies if refraction effects, e.g., due to significant local conductivity contrasts, with respect to the reported heat-flow value were present and if corrections were performed.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

perturbation flags

Allowed values

5 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/heat-flow-corrections/heat-refraction, in the IHFC Controlled Vocabularies as currently published.

C20 · expedition — Platform, Vessel, Expedition

Fact

Value

Field code

C20

Published column name

expedition

Name

Platform, Vessel, Expedition

Meaning

Specification of the expedition, cruise, platform or research vessel where the marine heat flow survey was conducted.

Type

string, up to 255 characters

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Guidance: Give the expedition cruise number, or the research vessel or drilling platform, in the forms [R/V Ship], [D/V Platform], [D/V Glomar Challenger], [D/V JOIDES Resolution] and [Expedition-Cruise number]. Source: Upload template.

C21 · probe_type — Probe type

Fact

Value

Field code

C21

Published column name

probe_type

Name

Probe type

Meaning

Type of heat-flow probe used for measurement.

Type

string

Unit

—

Obligation

Recommended (R)

Domain

Probe sensing (S)

Quality relevance

—

Allowed values

14 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/heat-flow-probes, in the IHFC Controlled Vocabularies as currently published.

C22 · probe_length — Probe length

Fact

Value

Field code

C22

Published column name

probe_length

Name

Probe length

Meaning

Length of marine heat-flow probe.

Type

number, 2 decimal places

Unit

m

Obligation

Recommended (R)

Domain

Probe sensing (S)

Quality relevance

—

Range

0 to 99.99

C23 · probe_tilt — Probe tilt

Fact

Value

Field code

C23

Published column name

probe_tilt

Name

Probe tilt

Meaning

Tilt of the marine heat-flow probe.

Type

number, 1 decimal places

Unit

degree

Obligation

Mandatory (M)

Domain

Probe sensing (S)

Quality relevance

M-score

Range

0 to 99.9

Rules

CF-2

C24 · Surface_temperature — Surface/Bottom-water temperature

Fact

Value

Field code

C24

Published column name

Surface_temperature (earlier spelling: water_temperature)

Name

Surface/Bottom-water temperature

Meaning

Seafloor temperature where surface heat-flow value (q) is taken. e.g. PT 100 or Mudline temperature for ocean drilling data.

Type

number, 2 decimal places

Unit

°C

Obligation

Optional (O)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-9.99 to 999.99

C25 · geo_lithology — Lithology

Fact

Value

Field code

C25

Published column name

geo_lithology

Name

Lithology

Meaning

Dominant rock type/lithology within the interval of heat-flow determination.

Type

string

Unit

—

Obligation

Optional (O)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

265 values, listed below

The allowed values come from the concept scheme http://resource.geosciml.org/classifierScheme/cgi/2016.01/simplelithology, in the vocabulary as currently published at https://geosciml.org/resource/vocabulary/cgi/2016/simplelithology.rdf.

Several values may be given in one cell, separated by ;. Source: Decision D-5.

C26 · geo_stratigraphy — Stratigraphic age

Fact

Value

Field code

C26

Published column name

geo_stratigraphy

Name

Stratigraphic age

Meaning

Stratigraphic age (series/epoch or stage/age) of the depth range involved in the reported heat-flow determination.

Type

string

Unit

—

Obligation

Optional (O)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

178 values, listed below

The allowed values come from the concept scheme http://resource.geosciml.org/vocabulary/timescale/gts2020, limited to the collection http://resource.geosciml.org/classifier/ics/ischart/GeochronologicEras, in the vocabulary as currently published at https://vocabs.ardc.edu.au/registry/api/resource/downloads/1211/isc2020.ttl.

Several values may be given in one cell, separated by ;. Source: Decision D-5.

C27 · T_grad_mean — Calculated or inferred temperature gradient

Fact

Value

Field code

C27

Published column name

T_grad_mean

Name

Calculated or inferred temperature gradient

Meaning

Mean temperature gradient measured for the heat-flow determination interval.

Type

number, 2 decimal places

Unit

K/km

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C28 · T_grad_uncertainty — Temperature gradient uncertainty

Fact

Value

Field code

C28

Published column name

T_grad_uncertainty

Name

Temperature gradient uncertainty

Meaning

Uncertainty (one standard deviation) of mean measured temperature gradient [T_grad_mean] as estimated by an error propagation from the uncertainty in the top and bottom temperature determinations or deviation from the linear regression of the temperature-depth data.

Type

number, 2 decimal places

Unit

K/km

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C29 · T_grad_mean_cor — Corrected temperature gradient

Fact

Value

Field code

C29

Published column name

T_grad_mean_cor

Name

Corrected temperature gradient

Meaning

Mean temperature gradient corrected for borehole (drilling/mud circulation) and environmental effects (terrain effects/topography, sedimentation, erosion, magmatic intrusions, paleoclimate, etc.). Name the correction method in the corresponding item.

Type

number, 2 decimal places

Unit

K/km

Obligation

Optional (O)

Domain

Borehole and mine (B)

Quality relevance

—

Range

-99999.99 to 99999.99

C30 · T_grad_uncertainty_cor — Corrected temperature gradient uncertainty

Fact

Value

Field code

C30

Published column name

T_grad_uncertainty_cor

Name

Corrected temperature gradient uncertainty

Meaning

Uncertainty (one standard deviation) of mean corrected temperature gradient [T_grad_mean_cor] as estimated by an error propagation from the uncertainty in the top and bottom temperature determinations or deviation from the linear regression of the temperature depth data.

Type

number, 2 decimal places

Unit

K/km

Obligation

Optional (O)

Domain

Borehole and mine (B)

Quality relevance

—

Range

-99999.99 to 99999.99

C31 · T_method_top — Temperature method (top)

Fact

Value

Field code

C31

Published column name

T_method_top

Name

Temperature method (top)

Meaning

Method used for temperature determination at the top of the heat-flow determination interval.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B)

Quality relevance

M-score

Allowed values

26 values, listed below

Rules

CF-1, CF-4

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/temperature-method, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/temperature-method/top, in the IHFC Controlled Vocabularies as currently published.

C32 · T_method_bottom — Temperature method (bottom)

Fact

Value

Field code

C32

Published column name

T_method_bottom

Name

Temperature method (bottom)

Meaning

Method used for temperature determination at the bottom of the heat-flow determination interval.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B)

Quality relevance

M-score

Allowed values

25 values, listed below

Rules

CF-1, CF-4

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/temperature-method, limited to the collection https://w3id.org/ihfc-iugg/vocabularies/temperature-method/bottom, in the IHFC Controlled Vocabularies as currently published.

C33 · T_shutin_top — Shut-in time (top)

Fact

Value

Field code

C33

Published column name

T_shutin_top

Name

Shut-in time (top)

Meaning

Time of measurement at the interval top in relation to the end values measured during the drilling are equal to zero.

Type

integer

Unit

hr

Obligation

Recommended (R)

Domain

Borehole and mine (B)

Quality relevance

—

Range

0 to 99999

C34 · T_shutin_bottom — Shut-in time (bottom)

Fact

Value

Field code

C34

Published column name

T_shutin_bottom

Name

Shut-in time (bottom)

Meaning

Time of measurement at the interval bottom in relation to the end values measured during the drilling are equal to zero.

Type

integer

Unit

hr

Obligation

Recommended (R)

Domain

Borehole and mine (B)

Quality relevance

—

Range

0 to 99999

C35 · T_corr_top — T correction method (top)

Fact

Value

Field code

C35

Published column name

T_corr_top

Name

T correction method (top)

Meaning

Applicable only if gradient correction for borehole effects is reported. Approach applied to correct the temperature measurement for drilling perturbations at the top of the interval used for heat-flow determination.

Type

string

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B)

Quality relevance

—

Allowed values

8 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/temperature-corrections, in the IHFC Controlled Vocabularies as currently published.

C36 · T_corr_bottom — T correction method (bottom)

Fact

Value

Field code

C36

Published column name

T_corr_bottom

Name

T correction method (bottom)

Meaning

Applicable only if gradient correction for borehole effects is reported. Approach applied to correct the temperature measurement for drilling perturbations at the bottom of the interval used for heat-flow determination.

Type

string

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B)

Quality relevance

—

Allowed values

8 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/temperature-corrections, in the IHFC Controlled Vocabularies as currently published.

C37 · T_number — Number of temperature recordings

Fact

Value

Field code

C37

Published column name

T_number

Name

Number of temperature recordings

Meaning

Number of discrete temperature points (e.g. number of used BHT values, log values or thermistors used in probe sensing) confirming the mean temperature gradient [T_grad_mean_meas]. Not the repetition of one measurement at a certain depth.

Type

integer

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Range

0 to 999999

C38 · q_date — Date of acquisition

Fact

Value

Field code

C38

Published column name

q_date

Name

Date of acquisition

Meaning

The entry gives the year of the acquisition of the temperature data (which may differ from the year of publication). If the month is unknown use 01, i.e. for the year 2005 use 2005-01. For non-unique time values, define a range in the format: ‘YYYY-MM; YYYY-MM’

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Format

YYYY-MM

C50 · T_top_mean — Temperature top

Fact

Value

Field code

C50

Published column name

T_top_mean

Name

Temperature top

Meaning

Absolute temperature at the top of the heat-flow interval used to calculate the temperature gradient.

Type

number, 2 decimal places

Unit

°C

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C51 · T_top_uncertainty — Temperature top uncertainty

Fact

Value

Field code

C51

Published column name

T_top_uncertainty

Name

Temperature top uncertainty

Meaning

Uncertainty of the absolute temperature at the top of the heat-flow interval used to calculate the temperature gradient.

Type

number, 2 decimal places

Unit

°C

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C52 · T_bot_mean — Temperature bottom

Fact

Value

Field code

C52

Published column name

T_bot_mean

Name

Temperature bottom

Meaning

Absolute temperature at the bottom of the heat-flow interval used to calculate the temperature gradient.

Type

number, 2 decimal places

Unit

°C

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C53 · T_bot_uncertainty — Temperature bottom uncertainty

Fact

Value

Field code

C53

Published column name

T_bot_uncertainty

Name

Temperature bottom uncertainty

Meaning

Uncertainty of the absolute temperature at the bottom of the heat-flow interval used to calculate the temperature gradient.

Type

number, 2 decimal places

Unit

°C

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

-99999.99 to 99999.99

C39 · tc_mean — Mean thermal conductivity

Fact

Value

Field code

C39

Published column name

tc_mean

Name

Mean thermal conductivity

Meaning

Mean conductivity in vertical direction representative for the interval of heat-flow determination. In best case, the value reflects the true in-situ conditions for the corresponding heat-flow interval.

Type

number, 2 decimal places

Unit

W/(mK)

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

0 to 99.99

C40 · tc_uncertainty — Thermal conductivity uncertainty

Fact

Value

Field code

C40

Published column name

tc_uncertainty

Name

Thermal conductivity uncertainty

Meaning

Uncertainty (one standard deviation) of mean thermal conductivity [tc_mean]

Type

number, 2 decimal places

Unit

W/(mK)

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Range

0 to 99.99

C41 · tc_source — Thermal conductivity source

Fact

Value

Field code

C41

Published column name

tc_source

Name

Thermal conductivity source

Meaning

Nature of the samples upon which thermal-conductivity was determined [tc_mean].

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

10 values, listed below

Rules

CF-3

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-sources, in the IHFC Controlled Vocabularies as currently published.

C42 · tc_location — Thermal conductivity location

Fact

Value

Field code

C42

Published column name

tc_location

Name

Thermal conductivity location

Meaning

Location of conductivity data used for heat-flow calculation.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

3 values, listed below

Rules

CF-3

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-location, in the IHFC Controlled Vocabularies as currently published.

C43 · tc_method — Thermal conductivity method

Fact

Value

Field code

C43

Published column name

tc_method

Name

Thermal conductivity method

Meaning

Method used for thermal-conductivity determination for [tc_mean].

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

15 values, listed below

Rules

CF-4

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-methods, in the IHFC Controlled Vocabularies as currently published.

C44 · tc_saturation — Thermal conductivity saturation

Fact

Value

Field code

C44

Published column name

tc_saturation

Name

Thermal conductivity saturation

Meaning

Saturation state of the studied rock interval studied for thermal conductivity [tc_mean].

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

7 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-saturation, in the IHFC Controlled Vocabularies as currently published.

C45 · tc_pT_conditions — Thermal conductivity pT conditions

Fact

Value

Field code

C45

Published column name

tc_pT_conditions

Name

Thermal conductivity pT conditions

Meaning

Qualified conditions of pressure and temperature under which the mean thermal conductivity [tc_mean] used for the heat-flow computation was determined.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

10 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-conditions, in the IHFC Controlled Vocabularies as currently published.

C46 · tc_pT_function — Thermal conductivity pT assumed function

Fact

Value

Field code

C46

Published column name

tc_pT_function

Name

Thermal conductivity pT assumed function

Meaning

Technique or approach used to correct the measured thermal conductivity towards in-situ pressure (p) and/or temperature (T) conditions.

Type

string

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Allowed values

42 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-pt-function, in the IHFC Controlled Vocabularies as currently published.

C47 · tc_number — TC number

Fact

Value

Field code

C47

Published column name

tc_number

Name

TC number

Meaning

Number of discrete conductivity determinations used to determine the mean thermal conductivity [tc_mean], e.g. number of rock samples with a conductivity value used, or number of thermistors used by probe sensing techniques. Not the repetition of one measurement on one rock sample or one thermistor.

Type

integer

Unit

—

Obligation

Mandatory (M)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

M-score

Range

0 to 9999

C48 · tc_strategy — Thermal conductivity averaging methodology

Fact

Value

Field code

C48

Published column name

tc_strategy

Name

Thermal conductivity averaging methodology

Meaning

Strategy that was employed to estimate the thermal conductivity [tc_mean] over the vertical interval of heat-flow determination.

Type

string

Unit

—

Obligation

Recommended (R)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Allowed values

6 values, listed below

The allowed values come from the concept scheme https://w3id.org/ihfc-iugg/vocabularies/conductivity-strategy, in the IHFC Controlled Vocabularies as currently published.

C49 · Ref_IGSN — IGSN

Fact

Value

Field code

C49

Published column name

Ref_IGSN

Name

IGSN

Meaning

International Generic Sample Numbers (IGSN, semicolon separated) for rock samples used for laboratory measurements of thermal conductivity in the heat flow calculation.

Type

string, up to 255 characters

Unit

—

Obligation

Optional (O)

Domain

Borehole and mine (B), Probe sensing (S)

Quality relevance

—

Several values may be given in one cell, separated by ;. Source: Fuchs et al. (2023), Appendix A.