# Departures from the paper The scheme follows Fuchs et al. (2023), with its corrigendum (Fuchs et al., 2026, Tectonophysics 934, 231226, ). The corrigendum corrects the paper's Tables 1 to 5, and says that the corrected scheme accords with version 2026.03 of the submission template and with version 0.2 of the data quality code, the Heat Flow Quality Analysis Toolbox. Where a corrected table gives a rule, the scheme applies it, and the page that states the rule cites the table. This page lists the places where the scheme still differs from the corrected paper, or fills a gap the paper leaves. Each departure says what the paper says, what the scheme does, why, and where the decision is recorded. Each departure is also stated where the rule lives. Entries with a source cite the GHFDB portal's decisions, which are linked by their headings. The {ref}`questions still open ` are listed at the end of the page. (dep-1)= ## DEP-1 The quality code has two full stops * **Paper.** Fig. 4 and Table 5 write the code with one full stop, as in `U1M2.xeTxXcx`. * **Scheme.** The code is written `U1.M2.xeTxXcx`, with two. * **Why.** The toolbox writes both full stops, and so does the portal. * **Source.** {{ decision(5) }}. (dep-2)= ## DEP-2 Heat refraction is R, and the flags follow the order of Fig. 4 * **Paper.** The corrected paper still contradicts itself. Its text and Fig. 4 write heat refraction as `R` and put surface-temperature variation fifth and convection sixth. Its Table 5 writes `h/H` and swaps the fifth and sixth characters. * **Scheme.** The flags are `S E T P V C R`, as in the text and Fig. 4. * **Why.** The text, Fig. 4, the website, the release paper and the toolbox agree. Table 5 is the outlier. * **Source.** {{ decision(6) }}. Stated at [Perturbation flags](perturbation-flags.md). (dep-3)= ## DEP-3 An uncertainty of zero is not determined * **Paper.** Corrected Table 1 classes a coefficient of variation below 5 % as `U1`. Read literally, an uncertainty of zero gives a coefficient of 0 % and so `U1`. * **Scheme.** A value or an uncertainty that is zero gives `Ux`, as does an empty one. * **Why.** The toolbox does so, and scored the 2024 release. * **Source.** Stated at [U-score](u-score.md). (dep-4)= ## DEP-4 The scores and their product are rounded to three decimal places * **Paper.** Fig. 3 gives the thresholds 0.75, 0.5 and 0.25, and the corrigendum places a product of exactly 0.25 in `M3`. The paper states no rounding. * **Scheme.** A T-score, a TC-score and their product are rounded to three decimal places before the product is classed. * **Why.** A sum of tenths such as 1 − 0.1 − 0.2 − 0.2 is 0.4999… in floating point. Rounding keeps a product that is exactly on a threshold from falling below it. The toolbox rounds too. * **Source.** {{ decision(7) }}. Stated at [M-score](m-score.md). (dep-5)= ## DEP-5 Only an empty input sets the missing-information mark * **Paper.** Section 3.2 gives the largest penalty for empty or unspecified fields, and adds an `x` to the M-score for both. The corrigendum leaves this text as it was, and its Table 5 sets the mark for an unspecified pT condition in some examples and not in others. * **Scheme.** An empty input takes the largest penalty with the mark. An input recorded as unspecified takes the same penalty without the mark. * **Why.** An unspecified input is a value the contributor gave, and an empty one is information that is missing. The toolbox applies the narrower rule. * **Source.** Stated at [the overview](index.md) and at [M-score](m-score.md). (dep-6)= ## DEP-6 A child is routed to a set of rules by its exploration method * **Paper.** Section 3.2 separates the scheme for probe sensing from the scheme for borehole and mine data. It does not say how a child is assigned to one of them, and has no result for a child that fits neither. * **Scheme.** The exploration method `P12` decides: the three probing methods select the probe-sensing rules, and drilling, clustered drilling, mining, tunnelling and the indirect method select the borehole and mine rules. `[Other]`, `[Unspecified]` and an empty method select none, and the M-score is `Mx`. * **Why.** The scheme needs one set of rules for each child. The toolbox routes by the exploration method, and the portal's vocabulary maps onto the toolbox's routing words as stated. * **Source.** {{ decision(17) }}. Stated at [the overview](index.md). Whether the mapping of each exploration method to its domain is right is open in . (dep-7)= ## DEP-7 An elevation at or above sea level has no water depth * **Paper.** Corrected Table 2 reads the water depth of a probe from the elevation, and gives penalties for depths of more than 1,500 m and more than 2,500 m. It does not consider an elevation at or above sea level. * **Scheme.** An elevation of zero or above has no water depth, and the criterion is treated as empty: the largest penalty with the mark, unless the bottom-water correction waives it. * **Why.** The table's depths are depths below sea level, so there is no value to score, which is what an empty input is. * **Source.** Stated at [Probe-sensing rules](probe-sensing.md). (dep-8)= ## DEP-8 The probe waivers read the temperature correction and the surface flag * **Paper.** Corrected Table 2 waives the tilt penalty when the in-situ correction `{corr_IS_flag}` is `[Tilt corrected]`, and the water depth penalty when `{corr_BWT_flag}` is `[Present and corrected]`. The template has no field `corr_BWT_flag`, and the vocabulary of the in-situ correction has no `[Tilt corrected]`. * **Scheme.** The tilt penalty is waived when the temperature correction `C12` `corr_T_flag` is `[Tilt corrected]`. The water depth penalty is waived when `C17` `corr_SUR_flag`, the field for surface and bottom-water temperature variation, is `[Present and corrected]`. * **Why.** The vocabulary of the temperature correction is the one that holds `[Tilt corrected]`. The in-situ correction `C11` takes the values for pressure and temperature considered. The paper's Appendix B calls `C17` the flag for surface and bottom-water temperature. * **Source.** {{ decision(11) }}. Stated at [Probe-sensing rules](probe-sensing.md). (dep-10)= ## DEP-10 A parent's code is inherited by a ranking the paper does not give * **Paper.** Section 3.4 and Fig. 5 say that the score of a single child is passed to the parent and that the poorest ranking of the relevant children is inherited. They do not say how the flags are chosen, or how a grade with the mark ranks against one without it. * **Scheme.** The U-score ranks `U1` to `U4`, then `Ux`. The M-score ranks `M1` to `M4`, then `M1x` to `M4x`, then `Mx`. The flags are taken whole from the child with the poorest U-score, the poorest M-score deciding a tie. A parent with one child inherits it whether or not it is marked relevant. A parent with several children and none relevant is not determined. * **Why.** The toolbox's inheritance answers both open points. The single child that is not marked relevant is the portal's addition, because the paper's single-child case does not depend on the mark. * **Source.** {{ decision(9) }}. Stated at [Inherited code](inherited-code.md). (dep-11)= ## DEP-11 A field that holds several values takes the poorest * **Paper.** Silent about a vocabulary field that holds more than one value. * **Scheme.** Every value is scored, and the largest penalty wins. * **Why.** One good value then never hides a poor one. The toolbox does so. * **Source.** {{ decision(8) }}. Stated at [the overview](index.md). (dep-12)= ## DEP-12 A borehole gradient is a continuous log only with the methods of a continuous log * **Paper.** Corrected Table 3 conditions the continuous log on more than three temperature recordings (`{T_number} >3`) and lists its methods. It states no condition for the multiple single points. * **Scheme.** A gradient is a continuous log only when it has more than three recordings and every method at the top and the bottom is `[LOGeq]`, `[cLOG]`, `[DTSeq]`, `[cDTS]` or `[LOGpert]`. Every other gradient is scored as multiple single points, with no condition on the count. * **Why.** The scheme needs one case for each gradient, and the table states a condition for the continuous log only. * **Source.** Stated at [Borehole and mine rules](borehole-and-mine.md). (dep-14)= ## DEP-14 Some borehole scores carry the mark where the paper gives none * **Paper.** Corrected Table 3 ends the scoring with a TC-score of 0.1 when no interval depth is reported, and Section 3.2.2.2 gives the penalty as −0.9. The table does not mention the mark for it, for a location that fits none of the three, or for a temperature method that fits no group of its case. * **Scheme.** The TC-score of 0.1 carries the missing-information mark. So does a borehole conductivity's location that fits none of the three values. A gradient whose methods fit no group of its case takes the case's largest penalty with the mark. * **Why.** An empty input the score needed carries the mark, and these are inputs the table could not score. The toolbox marks these cases. * **Source.** {{ decision(16) }}. Stated at [Borehole and mine rules](borehole-and-mine.md). (dep-16)= ## DEP-16 Table 5 of the corrected paper contradicts its own inputs and rules * **Paper.** Table 5 gives worked examples, and the corrigendum corrected several. It still contradicts Table 1 and its inputs in places: * It gives `U3` to examples B and C, whose uncertainty ratios are 3.1 % and 3.8 %, and to H, I and J, whose ratios are 5.0 %, 10.4 % and 8.8 %. Table 1 makes these `U1` and `U2`. * It sets the mark for an unspecified pT condition in the probe examples B and C, and not in the borehole examples G, I and J. * Its probe T-scores are 0.2 lower than the scheme's, because it applies the water depth penalty where `C17` is `[Present and corrected]`. * Well 3's inherited code is `M4`, although none of its children is, and one probe location's inherited code ignores the relevance flags. * Example I's erosion flag is written `r`, the letter of heat refraction. * In the probe columns, the method rows and the flag rows belong to different examples. * **Scheme.** The [worked examples](worked-examples.md) are the scores the rules of the scheme give each input. Where Table 5 and the rules disagree, the rules decide. * **Why.** An example that contradicts the rules it illustrates cannot test them. * **Source.** {{ decision(10) }}. (dep-17)= ## DEP-17 The U-score reads magnitudes and a percentage * **Paper.** Equation 2 writes `COV(%) = HFDunc / HFDmean`, which is a ratio and not a percentage. It does not say what a negative value or uncertainty means. * **Scheme.** The coefficient is the ratio of the magnitudes multiplied by 100, rounded to six decimal places. A negative heat flow is legitimate, so its uncertainty is a percentage of the value's magnitude. * **Why.** Table 1's classes are percentages, and a negative value must not be refused. * **Source.** Fuchs et al. (2023), Table 1, and the [edge cases](https://github.com/ihfc-iugg/ghfdb-portal/blob/main/specs/007-quality-scores/spec.md) of the portal's specification. Stated at [U-score](u-score.md). (departures-under-discussion)= ## Under discussion These places where the paper is ambiguous or contradicts itself are open with the data assessment team. The scheme is written as the departures above state it, and they stand until the questions are settled. * : which child's perturbation flags a parent takes when two children tie. * : how a conductivity measured with the continuous heating probe scores. * : whether an empty number of temperature recordings sets the mark for a borehole gradient. * : whether a gradient measured with `[DTSpert]` and more than three recordings is a continuous log, as the vocabulary's collection of continuous logs has it.